3 templates, 192 to 320 sf. DXF R2018, drawn in inches. Free, no signup.
DWG (R2000, converted from the DXF and round-trip verified). PNG is the plan-view render.
A framed platform off the back of the house, usually raised. Above 30 in from grade it needs a guard, and being attached to the house is what makes the ledger connection the thing that matters most about it. Typically 12 by 16 ft.
The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.
| Interior (W x D) | 12'-0" x 16'-0" |
|---|---|
| Floor area | 192 sf |
| Overall, outside face of wall | 12'-9" x 16'-10" |
| Workable range for this room type | 80 to 700 sf |
| Units | inches |
Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.
DXF (90 KB) DWG (31 KB) PNG (150 KB)
"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.
24 of 121 checks graded, zero defects. This template is published because it graded clean.
A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.
A paved surface at grade, off the back of the house. No guard, no framing and no footing schedule -- which is what separates it from a deck. Usually about 12 by 16 ft.
The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.
| Interior (W x D) | 16'-0" x 20'-0" |
|---|---|
| Floor area | 320 sf |
| Overall, outside face of wall | 16'-9" x 20'-10" |
| Workable range for this room type | 80 to 800 sf |
| Units | inches |
Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.
DXF (91 KB) DWG (32 KB) PNG (150 KB)
"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.
24 of 121 checks graded, zero defects. This template is published because it graded clean.
A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.
A roofed or open platform at an entry, at least 6 ft deep so two chairs and a person walking past can share it. Shallower than that and it is a stoop.
The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.
| Interior (W x D) | 9'-0" x 24'-0" |
|---|---|
| Floor area | 216 sf |
| Overall, outside face of wall | 9'-10" x 24'-9" |
| Workable range for this room type | 48 to 500 sf |
| Units | inches |
Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.
DXF (97 KB) DWG (34 KB) PNG (141 KB)
"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.
24 of 121 checks graded, zero defects. This template is published because it graded clean.
A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.
Code sections are cited for drafting context only. A room drawn to a dimension in a model code is not a compliance determination: adoption, amendment and interpretation are local, and the governing edition in your jurisdiction may differ from the one cited. Nothing here is stamped or sealed. Verify against the code your project is permitted under and the actual specified products. See the license and terms.