Block family

Exit Sign and Emergency Light CAD Blocks

The exit sign and the emergency light - two CAD blocks that appear on the egress sheet of almost every commercial set. Both are small: 12x4in for the sign, 8x5in for the light. They matter because of where they are, not how big they are. Free DXF downloads drawn to scale in inches.

2 blocks, 2 downloads on this page. DXF R2018, drawn in inches. Free, no signup.

Emergency Light 8in x 5in
Download Emergency Light Open in editor

DWG (R2000, converted from the DXF). PNG is the plan-view preview.

Emergency Light - plan view, 8in x 5in
Emergency Light - plan view, 8in x 5in

Exit Sign

Commercial Safety - datum: wall/ceiling mount point on wall line - default footprint 12in x 4in

Exit Sign - plan view CAD block
Exit Sign - plan view, 12in x 4in

Illuminated egress marking at required exits and at each change of direction where the way out is not self-evident. The electrical engineer draws and circuits it, but it belongs to the architect's egress plan, which is where arrow direction gets settled.

Sizing

12 x 4 in is a single-face edge-lit or thermoplastic sign. The 9 to 16 in width runs from a compact LED unit up to a double-face or arrow-equipped housing. The 3 to 6 in depth is projection off the wall face: thin for an edge-lit panel, deeper once there is a housing and back box behind it.

Drafting notes

One datum on the wall line covers both the wall-mounted and the ceiling-mounted condition, so the same block serves either. Move ceiling-mounted signs onto a reflected-ceiling layer so they do not pile onto wall-mounted ones in plan. Carry face count and arrow direction as attributes, since those two values are what the sign schedule exists to hold.

Drawn alongside

Cross-checked against the emergency light: a corridor that needs a sign at a change of direction usually needs illumination at the same turn, and the two get tallied on one life-safety sheet.

Dimensions

Plan footprint (W x H)12in x 4in
Unitsinches
DXF versionR2018
Insertion datumwall/ceiling mount point on wall line

Parameters

ParameterDefaultRange / options
Width12in9in–16in
Depth4in3in–6in

Download

Relevant standards

IBC Chapter 10 (Means of Egress)
Governs where exit signs are required and sets the spacing driver: no point in an exit access corridor more than 100 ft, or the sign's listed viewing distance, from the nearest visible sign.
NFPA 101 Life Safety Code
Its marking-of-means-of-egress chapter covers the same ground for jurisdictions that adopt NFPA 101 instead of, or alongside, the IBC.

Emergency Light

Commercial Safety - datum: wall-mount point on wall line - default footprint 8in x 5in

Emergency Light - plan view CAD block
Emergency Light - plan view, 8in x 5in

Battery-backed twin-head unit that keeps the egress path lit when normal power drops. The electrical engineer places it on corridors, stair landings and the exterior discharge; the architect then checks that placement against the egress diagram, since coverage is judged on the path, not on device count.

Sizing

At 8 x 5 in the block reads as a compact LED twin-head housing. Push the width toward 12 in for a standard thermoplastic unit carrying a larger sealed battery, or for a wet-location or vandal-resistant housing. The 4 to 6 in depth is how far the body and the swiveling lamp heads stand off the wall face.

Drafting notes

The block origin sits on the wall line, so depth projects into the room the moment you insert and no trim-back is needed. Rotate it to face the corridor run it lights. Keep it on a life-safety layer rather than general power so the egress sheet can be isolated for plan review.

Drawn alongside

Drawn with the exit sign, since combination sign-and-light housings are common and a combination unit should show as one symbol rather than two blocks stacked on the same wall point.

Dimensions

Plan footprint (W x H)8in x 5in
Unitsinches
DXF versionR2018
Insertion datumwall-mount point on wall line

Parameters

ParameterDefaultRange / options
Width8in6in–12in
Depth5in4in–6in

Download

Relevant standards

IBC Chapter 10 (Means of Egress)
Sets where an emergency electrical system has to illuminate the egress path and the 90-minute minimum duration for that supply.
NFPA 101 Life Safety Code
Carries its own emergency lighting provisions, including illumination levels measured at floor level; which document governs comes down to what the jurisdiction adopted.

Standards are listed for drafting context only. A symbol drawn to a convention is not a compliance determination - verify against the governing code and the specified product. See the license and terms.

Related families

All 33 block families

Egress devices, ready to place.

Exit signage and emergency lighting for the life-safety sheet. Open one in the editor or take the DXF.

Whole library

Get the entire library - all 219 blocks as one ZIP

Every category, every MEP orientation, DXF R2018, sorted into folders. Tell us where to send it and the download starts immediately.