Block family

HVAC Duct Elbow CAD Blocks

The 45-degree and 90-degree HVAC duct elbow CAD blocks, each drawn in all four compass turns - northeast, northwest, southeast, southwest - so the fitting on the sheet points the way the run actually goes. Duct is double-line parametric here, not a single-line schematic, so the width you set is the width that plots. Eight DXF downloads across two base blocks.

2 blocks, 8 downloads on this page. DXF R2018, drawn in inches. Free, no signup.

HVAC Duct 45-degree Elbow (Northeast) 14in x 23.9in
Download HVAC Duct 45-degree Elbow (Northeast) Open in editor

DWG (R2000, converted from the DXF). PNG is the plan-view preview.

HVAC Duct 45-degree Elbow (Northeast) - plan view, 14in x 23.9in
HVAC Duct 45-degree Elbow (Northeast) - plan view, 14in x 23.9in

HVAC Duct 45-degree Elbow (Northeast)

HVAC Duct (MEP) - datum: bend vertex (0,0); axis leg + 45deg leg into orient quadrant - default footprint 14in x 23.9in

HVAC Duct 45-degree Elbow (Northeast) - plan view CAD block
HVAC Duct 45-degree Elbow (Northeast) - plan view, 14in x 23.9in

Used far more often as half of an offset than as a turn in its own right. Two of them with a short run between shift a trunk sideways past a beam, a light fixture or another trade's line, at a fraction of the pressure loss and the corner clearance a pair of 90s would demand.

Sizing

One leg lies on axis and the other on the diagonal, so the footprint is lopsided at 14 x 23.9in for u=16, width=10, and those extents come off the swept walls rather than the leg length. Sharing the same fixed 4in inside corner as the 90, the bend center sits (4 plus width/2) over sin 22.5 degrees from the vertex, roughly 23.5in at defaults.

Drafting notes

Bend vertex is the datum, same as the 90, so an offset is built by inserting this block, a run, then the opposite-quadrant variant. Give that intermediate run real length. Two bends stacked nose to tail leave the second working in a distorted velocity profile, and published loss coefficients all assume an approach that is not already swirling.

Drawn alongside

Comes in mirrored pairs with a straight run between, the NE variant working against the SE or NW depending which way the trunk shifts. Where the offset also changes duct size, the transition belongs on that run, not on either bend.

Dimensions

Plan footprint (W x H)14in x 23.9in
Unitsinches
DXF versionR2018
Insertion datumbend vertex (0,0); axis leg + 45deg leg into orient quadrant

Parameters

ParameterDefaultRange / options
OrientationNENE / NW / SE / SW
Nominal size16in6in–96in
Width10in4in–48in

Download

Also: NE NW SE SW

Relevant standards

SMACNA HVAC Systems Duct Design
The design-side companion to the construction standards: fitting selection, equivalent length, and the layout of offsets around structure and other trades.

HVAC Duct 90-degree Elbow (Northeast)

HVAC Duct (MEP) - datum: bend vertex (0,0); two ports at u along the two orient dirs - default footprint 21in x 21in

HVAC Duct 90-degree Elbow (Northeast) - plan view CAD block
HVAC Duct 90-degree Elbow (Northeast) - plan view, 21in x 21in

A square-duct 90-degree turn, drawn where the trunk follows the building around a column, a beam line or a shaft wall. On the air side it is usually the most expensive single fitting in the run, so the throat treatment - radius, miter, vanes - belongs in a note rather than left to the fabricator.

Sizing

u is the leg length from bend vertex to each port and width is the duct dimension, so the footprint is u plus half a width on both axes: 21in square at u=16, width=10. Throat radius is not a parameter. The block sweeps concentric walls off a fixed 4in inside corner, so the drawn centerline R/W works out to 0.5 plus 4/W - about 0.9 on a 10in duct, 0.58 on a 48in one.

Drafting notes

Insert on the intersection of two centerlines; the vertex is the datum and the outer wall swings half a width past it. Draw the elbow you intend to build. At R/W 1.5 a 36in duct puts the tangent point 54in back from the corner on each leg, a real clash with structure and the whole reason mitered-and-vaned elbows exist. Vanes get called out, never inferred.

Drawn alongside

Sits between two straight runs and takes their tagged size. Where the turn is really an offset around an obstruction, a mirrored pair of 45s replaces it. Vane and rail construction comes off the SMACNA plates, not out of this symbol.

Dimensions

Plan footprint (W x H)21in x 21in
Unitsinches
DXF versionR2018
Insertion datumbend vertex (0,0); two ports at u along the two orient dirs

Parameters

ParameterDefaultRange / options
OrientationNENE / NW / SE / SW
Nominal size16in6in–96in
Width10in4in–48in

Download

Also: NE NW SE SW

Relevant standards

ASHRAE Duct Fitting Database
Source of the loss coefficients for radius, mitered and vaned elbows as a function of R/W and aspect ratio. Coefficients are referenced to a velocity pressure, so a tight elbow in a fast trunk costs far more than the same elbow in a slow one.
SMACNA HVAC Duct Construction Standards - Metal and Flexible
Elbow construction details, including single-thickness and double-thickness turning vanes and the rails they mount to. Double thickness is not automatically the lower-loss choice; it buys rigidity, and published performance depends on vane spacing and velocity.

Standards are listed for drafting context only. A symbol drawn to a convention is not a compliance determination - verify against the governing code and the specified product. See the license and terms.

Related families

All 33 block families

Turn the elbow before you place it.

Duct width and radius are parameters. Open one in the editor, size it to the run, then export the DXF.

Whole library

Get the entire library - all 219 blocks as one ZIP

Every category, every MEP orientation, DXF R2018, sorted into folders. Tell us where to send it and the download starts immediately.

One email, when there is something worth telling you. No spam, ever. Prefer not to? Take the ZIP without giving an email.